This is the latest recevied telemetry packets stored in our database for station/object KH6UU-9. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Battery* | Temp* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1775304189 | 399 Volts | 603 Deg.F | 317 | 0 | 0 |
| 1775302383 | 391 Volts | 603 Deg.F | 317 | 0 | 0 |
| 1775296993 | 397 Volts | 603 Deg.F | 316 | 0 | 0 |
| 1775295195 | 391 Volts | 604 Deg.F | 317 | 0 | 0 |
| 1775282616 | 395 Volts | 610 Deg.F | 310 | 0 | 0 |
| 1775279020 | 390 Volts | 614 Deg.F | 307 | 0 | 0 |
| 1775277223 | 381 Volts | 616 Deg.F | 301 | 0 | 0 |
| 1775275425 | 394 Volts | 618 Deg.F | 294 | 0 | 0 |
| 1775268228 | 395 Volts | 625 Deg.F | 286 | 0 | 0 |
| 1775266429 | 394 Volts | 623 Deg.F | 292 | 0 | 0 |
| 1775185164 | 447 Volts | 631 Deg.F | 275 | 0 | 0 |
| 1775185066 | 450 Volts | 631 Deg.F | 279 | 0 | 0 |
| 1775184907 | 445 Volts | 631 Deg.F | 277 | 0 | 0 |
| 1775184835 | 448 Volts | 631 Deg.F | 279 | 0 | 0 |
| 1775184821 | 441 Volts | 631 Deg.F | 272 | 0 | 0 |
| 1775184669 | 440 Volts | 632 Deg.F | 273 | 0 | 0 |
| 1775184564 | 441 Volts | 633 Deg.F | 274 | 0 | 0 |
| 1775184504 | 440 Volts | 632 Deg.F | 273 | 0 | 0 |
| 1775184443 | 438 Volts | 632 Deg.F | 275 | 0 | 0 |
| 1775184384 | 439 Volts | 632 Deg.F | 273 | 0 | 0 |
| 1775184324 | 440 Volts | 632 Deg.F | 275 | 0 | 0 |
| 1775184318 | 437 Volts | 632 Deg.F | 275 | 0 | 0 |
| 1775184236 | 434 Volts | 632 Deg.F | 273 | 0 | 0 |
| 1775184201 | 426 Volts | 631 Deg.F | 274 | 0 | 0 |
| 1775184138 | 439 Volts | 631 Deg.F | 277 | 0 | 0 |
*Used Equation Coefficients:
Battery: 0, 1, 0
Temp: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)