This is the latest recevied telemetry packets stored in our database for station/object SP7MP-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1793311549 | 640 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793309749 | 639 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793307948 | 638 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793306147 | 637 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793304347 | 636 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793302546 | 635 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793300745 | 634 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793298945 | 633 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793297144 | 632 Count | 128 Count | 41 Count | 3.98 VDC | 0 VDC |
| 1793295343 | 619 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793293543 | 618 Count | 116 Count | 29 Count | 3.99 VDC | 0 VDC |
| 1793291759 | 617 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793289958 | 616 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793288157 | 615 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793286356 | 614 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793284555 | 613 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793282754 | 612 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793280953 | 611 Count | 116 Count | 29 Count | 3.98 VDC | 0 VDC |
| 1793279152 | 610 Count | 116 Count | 29 Count | 3.99 VDC | 0 VDC |
| 1793277352 | 605 Count | 112 Count | 25 Count | 3.98 VDC | 0 VDC |
| 1793275551 | 604 Count | 112 Count | 25 Count | 3.98 VDC | 0 VDC |
| 1793273746 | 603 Count | 112 Count | 25 Count | 3.99 VDC | 0 VDC |
| 1793271950 | 602 Count | 112 Count | 25 Count | 3.98 VDC | 0 VDC |
| 1793270149 | 601 Count | 112 Count | 25 Count | 3.98 VDC | 0 VDC |
| 1793268348 | 600 Count | 112 Count | 25 Count | 3.98 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)