This is the latest recevied telemetry packets stored in our database for station/object SR2GKG-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1776496255 | 75 Count | 122 Count | 69 Count | 4.42 VDC | 0 VDC |
| 1776494455 | 49 Count | 77 Count | 44 Count | 4.4 VDC | 0 VDC |
| 1776492654 | 4 Count | 3 Count | 0 Count | 4.39 VDC | 0 VDC |
| 1776490861 | 596 Count | 995 Count | 576 Count | 4.4 VDC | 0 VDC |
| 1776489060 | 555 Count | 905 Count | 536 Count | 4.41 VDC | 0 VDC |
| 1776487259 | 515 Count | 840 Count | 497 Count | 4.41 VDC | 0 VDC |
| 1776485459 | 477 Count | 779 Count | 460 Count | 4.39 VDC | 0 VDC |
| 1776483658 | 439 Count | 717 Count | 423 Count | 4.41 VDC | 0 VDC |
| 1776481857 | 408 Count | 668 Count | 393 Count | 4.42 VDC | 0 VDC |
| 1776480057 | 354 Count | 587 Count | 340 Count | 4.4 VDC | 0 VDC |
| 1776478256 | 318 Count | 527 Count | 305 Count | 4.42 VDC | 0 VDC |
| 1776476455 | 283 Count | 470 Count | 271 Count | 4.4 VDC | 0 VDC |
| 1776474654 | 247 Count | 409 Count | 236 Count | 4.39 VDC | 0 VDC |
| 1776472854 | 216 Count | 356 Count | 206 Count | 4.42 VDC | 0 VDC |
| 1776471053 | 181 Count | 302 Count | 172 Count | 4.42 VDC | 0 VDC |
| 1776469259 | 145 Count | 248 Count | 141 Count | 4.38 VDC | 0 VDC |
| 1776467459 | 112 Count | 195 Count | 109 Count | 4.39 VDC | 0 VDC |
| 1776465658 | 78 Count | 137 Count | 76 Count | 4.38 VDC | 0 VDC |
| 1776463857 | 52 Count | 92 Count | 51 Count | 4.41 VDC | 0 VDC |
| 1776462057 | 25 Count | 44 Count | 25 Count | 4.39 VDC | 0 VDC |
| 1776460256 | 599 Count | 1013 Count | 567 Count | 4.4 VDC | 0 VDC |
| 1776458455 | 574 Count | 969 Count | 543 Count | 4.39 VDC | 0 VDC |
| 1776456655 | 553 Count | 931 Count | 523 Count | 4.39 VDC | 0 VDC |
| 1776454854 | 529 Count | 883 Count | 500 Count | 4.41 VDC | 0 VDC |
| 1776453053 | 507 Count | 840 Count | 479 Count | 4.41 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)