This is the latest recevied telemetry packets stored in our database for station/object OK1OBR-12. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1781394518 | 349 Count | 164 Count | 43 Count | 0 VDC | 0 VDC |
| 1781392714 | 348 Count | 163 Count | 43 Count | 0 VDC | 0 VDC |
| 1781390910 | 347 Count | 163 Count | 43 Count | 0 VDC | 0 VDC |
| 1781389106 | 346 Count | 162 Count | 43 Count | 0 VDC | 0 VDC |
| 1781387302 | 345 Count | 162 Count | 43 Count | 0 VDC | 0 VDC |
| 1781385499 | 344 Count | 161 Count | 43 Count | 0 VDC | 0 VDC |
| 1781383695 | 343 Count | 161 Count | 43 Count | 0 VDC | 0 VDC |
| 1781381891 | 342 Count | 160 Count | 43 Count | 0 VDC | 0 VDC |
| 1781380087 | 341 Count | 160 Count | 43 Count | 0 VDC | 0 VDC |
| 1781378283 | 340 Count | 160 Count | 43 Count | 0 VDC | 0 VDC |
| 1781376479 | 339 Count | 160 Count | 43 Count | 0 VDC | 0 VDC |
| 1781374675 | 338 Count | 159 Count | 43 Count | 0 VDC | 0 VDC |
| 1781372917 | 337 Count | 159 Count | 43 Count | 0 VDC | 0 VDC |
| 1781371113 | 336 Count | 158 Count | 43 Count | 0 VDC | 0 VDC |
| 1781369309 | 335 Count | 158 Count | 43 Count | 0 VDC | 0 VDC |
| 1781367506 | 334 Count | 158 Count | 43 Count | 0 VDC | 0 VDC |
| 1781365702 | 333 Count | 158 Count | 43 Count | 0 VDC | 0 VDC |
| 1781363898 | 332 Count | 157 Count | 43 Count | 0 VDC | 0 VDC |
| 1781362094 | 331 Count | 157 Count | 43 Count | 0 VDC | 0 VDC |
| 1781360290 | 330 Count | 156 Count | 43 Count | 0 VDC | 0 VDC |
| 1781358486 | 329 Count | 156 Count | 43 Count | 0 VDC | 0 VDC |
| 1781356682 | 328 Count | 156 Count | 43 Count | 0 VDC | 0 VDC |
| 1781354878 | 327 Count | 156 Count | 43 Count | 0 VDC | 0 VDC |
| 1781353074 | 326 Count | 155 Count | 43 Count | 0 VDC | 0 VDC |
| 1781351316 | 325 Count | 155 Count | 43 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)